Application
LV Aerial Bundle Cables are designed to supply 600/1000 volt aerial service for temporary service at construction sites, as a service drop (power pole to service entrance), as a secondary cable (pole to pole) or street lighting.
Construction
Phase Conductor: AAC1350, Neutral Conductor:AAC1350 /AAAC1120/AAAC6201/ACSR,Insulation:PE/XLPE/PVC/LDPE/HDPE.
Parameter/Data Sheet
Please click or download below LV ABC Cable pdf to check the parameter regard to BS 7870 / TNB Specification(IEC 60502) / HD 626 S1 / NFC 33-209 / AS/NZS 3560-1 standards.
British Standard 600 1000V ABC –Aerial Bundled Cables to BS 7870-5.docx.pdf
Australian Standard 600 1000V ABC –Aerial Bundled Cables to ASNZS 3560.1.docx.pdf
French Standard 600 1000V ABC –Aerial Bundled Cables to NFC 33-209.docx.pdf
German Standard AsXSn 600 1000V ABC –Aerial Bundled Cables to PN HD 626 4F-.docx.pdf
German Standard 600 1000V ABC –Aerial Bundled Cables to HD 626 S1.docx.pdf
IEC Standard 6001000V ABC –Aerial Bundled Cables to IEC 60502.docx.pdf
German Standard NFA2X 600 1000V ABC –Aerial Bundled Cables to VDE 0274(Z)-.DOCX.pdf
German Standard E-A2Y 600 1000V ABC –Aerial Bundled Cables to HD 626 3A.docx.pdf
American Standard Duplex 600 1000VABC Service Drop Cable to IECA-S-76-474.pdf
American Standard Triplex 600 1000V ABC Service Drop Cable to IECA-S-76-474.pdf
American Standard Quadruplex 600 1000V ABC Service Drop Cable to IECA-S-76-474.pdf
Aerial Bundle Cable (ABC cable) is a very innovative concept for overhead power distribution as compared to the conventional bare conductor overhead distribution system.
It provides higher level of safety and reliability, lower power losses and ultimate system economy by reducing installation, maintenance and operative cost.
This over-head cable provides reinforced insulation acc. IEC 61140 and fulfill therefore Class II acc. IEC 61140. It is not flame retardant. But this could be if requested change to a flame retardant cable.
Electrical Properties | |||
Rated voltage | 0.6/1KV | Minimum Bending Radius | 18×OD |
Cores | 1,2,3, 4, 3+1,4+1 etc. | Phase Conductor | Aluminium (AAC) |
Section | 10mm2~120mm2 | Neutral Conductor | AAAC/ACSR |
Minimum Laying Temperature | -20°C | Insulation | XLPE/ PE/ PVC/ LEPE/ HDPE, UV-resistant |
Operating Temperature | -40°C~ +90°C | Standards | NFC 33-209/ BS 7870-5/ IEC 60502/AS/NZS or according to your requirement. |
Maximum Short-circuit Temperature | 250°C | Application | Overhead power transmission. |
Maximum Conductor Temperature | 80°C | Core Identification | 1, 2 resp. 3 raised longitudinal ribs on the surface of the cores. The surface of the neutral core should have at least 12 ribs for cross-sections up to 50 mm^2 and a minimum of 16 ribs for cores above 50 mm^2. In the case of five core bundles the surface of the protective core should be smooth. |